spacer
Now Shipping Internationally
Deal of the Day
a new offer every day!

On Sale Now | Best Sellers | Contractor Registration

(800) 837- 8175
9:00 AM – 5:00 PM EST
My Account: Log in
0 item(s) $0.00
view cart
Batteries & Power
Batteries
Battery Cabinets & Racks
Battery Chargers & Test Equipment
Power Supplies & Transformers
Terminal Cabinets
TVSS Devices (Surge Protection)
UPS Systems
Cameras & CCTV
Cables & Connectors
CCTV Monitors
DVR
Security Cameras
Clock Systems
Digital OR & ICU Timers
Digital Secondary clocks
Master Clocks
Secondary Clocks
Fire & Life Safety
Annunciators
Code & Training Books
Communicators (DACT)
Control Panels
Devices
Faraday Products
FCI Products
Integration Accessories
Mass Notification
Obsolete Parts
Owner's Manuals
Relays
Signals
Test Equipment
Voice Evacuation
Property Protection
Buttons & Switches
Device Covers
DVR and VCR Lock-Boxes
Environmental Controls
Signage
Security & Intrusion
Door & Window Contacts
Driveway Alarms
Entrance Alarms
Environmental Sensors
Exit Alarms
Expansion Modules & Accessories
Glassbreak Sensors
Keypads
Holdup & Panic Alarms
Keyfobs & Remotes
Life Safety Devices
Motion Detectors
Panels
Personal Emergency Response
Phone, Cellular and Internet Dialers
Pool Alarms
RF Receivers
Sirens, Speakers and Strobes
Wired Home & Business Security Systems
Wireless Home & Business Security Systems
Tools
Cables & Connectors
Compression Tools
Crimping Tools
Electrical Tape
Installation Tools
Miscellaneous Tools
Punch Down Tools
Staplers & Staples
Stripping & Cable Cutting Tools
Testing Tools
Tool Kits
Wiring Tools
Wire & Cable
Aquaseal FPL and PLTC Listed Water-Resistant Cable
Audio Cable
CCTV Wire
Coaxial Cable
FPL Cable
Low-Voltage Cable (Non-Fire)
Metal-Clad (MC) Cable
Network & Data Cable
NPLF Cable
NPLFP Cable
Plenum-Rated (FPLP)
Riser-Rated (FPLR)
Tools

Discussion on Utilitizing VOIP as a Means of Transmitting a Fire Alarm Signal

Posted by Administrator on 4/12/2012 to LinkedIn Discussions
Question: Looking to generate discussion on utilizing VOIP as a means of transmitting a fire alarm signal in lieu of POTS. Please share your positive or negative experiences.
Read More

Purpose of Listing Fire Alarm Components

Posted by Administrator on 4/11/2012 to LinkedIn Discussions
Question:   I would like to ask what is the reason or purpose of listing fire alarm systems and components. I don't need the procedure or the definition, that is spelled out in NFPA 72. But what is the reason to start with? My first assumption is that it is used because most fire alarm companies do not have the expertise or capabilities to determine if components (relays, etc.) are compatible with the control equipment and also that they meet the basic requirements spelled out in NFPA 72.
Read More

Grounding and Bonding of Gas Piping in Buildings

Posted by Mike Agri on 3/19/2012 to LinkedIn Discussions

The following is a comment from a Linked-In discussion concerning grounding and bonding of gas piping in buildings. It is a critical piece to understand when attempting to differentiate between GROUNDING and BONDING. The difficulty arises because bonding, in most cases, achieves at least some degree of grounding as well, but the intent, methods, and applicable conductors can be significantly different.

Read More

Lightning & Surge Protection 101 - Part 5

Posted by Mike Agri on 1/26/2012 to Understanding Alarms

Today, wireless systems for telephone, alarms, security, and other applications are all the rage. Here is a cautionary tale.

  • At one time, IBM, and later Simplex Time Recorder Company, manufactured electronic, self-correcting clock systems that employed a high power frequency generator wired in parallel across the electrical service. The last minute of every hour, the frequency generator would be turned on for a fixed period of time, and insert one of several available frequencies on the entire AC distribution system in the entire building. The secondary clocks, which plugged into any available single phase, 2-wire 120V outlet, each contained a signal amplifier which turned the frequency into a voltage that would energize a solenoid operated correction mechanism in each clock for system-wide synchronization. It was discovered that If two relatively proximate facilities running on the same utility feed just happened to be set to correct using the same frequencies, it would sometimes result in cross talk between building clock systems which might have one or both facilities with a slightly different Master Clock time setting cause an adjacent facility to also go into correction, with the usual result of each or both systems advancing, every hour.
Read More

Lightning & Surge Protection 101 - Part 4

Posted by Mike Agri on 1/13/2012 to Understanding Alarms

When people ask me what I do, my usual response is, "I'm the last guy that gets called to fix something after everybody else who could possibly screw it up has been brought in and has failed to find or fix the problem, and usually, only after sins of the installer or subsequent service\installation people have been obscured or exacerbated by subsequent repair or troubleshooting attempts." Over the course of a career, a manufacturer's technical representative gets to see about every kind of "equipment failure" imaginable, and even some that aren't so imaginable.

Read More

 LinkedIn Discussions
 Site Features
 Understanding Alarms

 Discussion on Utilitizing VOIP as a Means of Transmitting a Fire Alarm Signal
 Purpose of Listing Fire Alarm Components
 Grounding and Bonding of Gas Piping in Buildings
 Lightning & Surge Protection 101 - Part 5
 Lightning & Surge Protection 101 - Part 4

 April 2012
 March 2012
 January 2012
 December 2011
 October 2011
Like us on Facebook
Follow us on Twitter!
Subscribe to our blog!
spacer
TC Life Safety BBB Business Review Nextag Rating TC Life Safety Systems is an Upfront Merchant on TheFind. Click for info. Find Us on Facebook
 
Resources Contacts About Us
Customer Support Address & Phone Numbers Blog New!
Industry Topics Contact Form Case Studies
Newsletters Customer Registration Company History
Sitemap Fax Order Form Professional Licencing
Testimonials Request a Quote Trade Associations
Subscribe to our Newsletter
Enter your email address below to receive
our monthly newsletter.
spacerView Back Issues
Terms and Conditions |  Privacy Statement |  Disclaimer |